campus build · FL · flagship tier
Flagship campus
The full space programme: every space type in the standard, a design studio and a model room for BIM and digital twins.
at a glance
Size and capacity
- Tier: Flagship
- Modules: 194
- Floors: 2
- Floor area: about 2 716 m2
- Learners at one time: 403
- Rooms: 47
Used for. A township or large-city campus. All seven levels are taught on site, and the other campuses book its labs.
space schedule
Spaces, modules and seats
| Space | Group | Count | Modules | Seats |
|---|---|---|---|---|
| Open learning studio | Learn | 6 | 24 | 180 |
| Assembly room | Learn | 4 | 16 | 120 |
| BIM design studio | Learn | 1 | 4 | 24 |
| Model room for digital twins | Learn | 1 | 2 | 8 |
| Project room | Collaborate | 4 | 8 | 24 |
| Brainstorm room | Collaborate | 2 | 4 | 8 |
| Meeting room | Collaborate | 2 | 4 | 20 |
| Silent study area | Focus | 1 | 3 | 27 |
| Quiet room | Focus | 2 | 2 | 4 |
| Library with 12 reading cubicles | Focus | 1 | 4 | 12 |
| Open workstation area | Work | 1 | 28 | 90 |
| Staff and leadership offices (seven offices) | Work | 1 | 11 | 7 |
| Coffee bar | Care | 1 | 6 | 20 |
| Staff pantry | Care | 1 | 3 | 8 |
| Restaurant | Care | 1 | 11 | 44 |
| Relaxation and rest room | Care | 1 | 6 | 12 |
| Locker room and fitting rooms | Care | 1 | 5 | 12 |
| Gaming and play zone | Care | 1 | 3 | 8 |
| Reception | Welcome | 1 | 3 | 4 |
| Lounge | Welcome | 1 | 6 | 16 |
| Store and server rooms | Support | 1 | 3 | - |
| Washrooms, both floors | Support | 1 | 9 | - |
| Corridors, stairs and lobbies | Support | - | 29 | - |
| Total | 194 | 648 |
- About one module in seven is kept for corridors, stairs and lobbies, so routes stay wide and clear.
- Assembly rooms sit in pairs with a folding wall between them, so two rooms join into one hall for 60.
- The restaurant and the washrooms use block walls and their own extract, as the interiors standard asks.
- The flagship has a twin campus in a different hazard zone, so learners and records can move if one is closed.
element list
Coded elements and quantities
Every line uses a code from the element library. No maker is named. Quantities are worked out from the space schedule by the rules of the standard.
| Code | Element | Quantity | Unit |
|---|---|---|---|
| CS-SH-01 | Module shell, 2.4 x 5.8 x 2.9 m | 194 | each |
| CS-SH-02 | Terrace module with guard rail | 4 | each |
| CS-SH-03 | Straight stair, single flight | 2 | each |
| CS-SH-04 | Wide stair, dog-legged or L-shaped | 2 | each |
| CS-SH-05 | Glass curtain wall panel | 66.0 | m2 |
| CS-SH-06 | Sliding glass door | 12 | each |
| CS-SH-08 | Access ramp, step-free entrance | 2 | each |
| CS-SH-09 | Platform lift, one storey | 2 | each |
| CS-IN-03 | Folding partition | 120 | m2 |
| CS-IN-05 | Floor finish, dry areas | 2 310 | m2 |
| CS-IN-06 | Floor and wall finish, wet areas | 406 | m2 |
| CS-IN-07 | Fire-exit door with push bar | 8 | each |
| CS-FU-01 | Linear workstation | 90 | each |
| CS-FU-02 | Meeting table set, 10 seats | 2 | each |
| CS-FU-03 | Phone booth | 10 | each |
| CS-FU-04 | Meeting pod, 4 seats | 4 | each |
| CS-FU-05 | Library shelf bay | 8 | each |
| CS-FU-06 | Learner seat | 403 | each |
| CS-SV-01 | Sub-board, per floor | 9 | each |
| CS-SV-02 | Cooling unit, per room | 47 | each |
| CS-SV-03 | Smoke detector and sounder group | 49 | each |
| CS-SV-04 | Comms cabinet | 2 | each |
| CS-SV-05 | Solar array, roof | 116 | kW |
| CS-SV-06 | Emergency light and exit sign group | 51 | each |
Reference design v0.1. Planning values for teaching and early design. A licensed local engineer and the local authority confirm every real project.
build order
How it is put together
- Site works: base, drainage, the fire-service route and the assembly area.
- Build in three phases so teaching can start early: studios and washrooms first, then work and care spaces, then the library, labs and restaurant.
- For each phase: place ground modules, stairs, upper modules and terraces, then seal the roof.
- Run and test services phase by phase. The fire panel and the meters are live before any room opens.
- Finishes, furniture and signs, then the as-built model, the certificate list and the maintenance plan.
model files
File names for this build
C01-B1-L1-ARC: architecture model, floor 1C01-B1-L1-STR: structure model, floor 1C01-B1-L1-MEP: services model, floor 1C01-B1-L2-ARC: architecture model, floor 2- Replace C01 with the number of the real campus. The element code follows when a file holds one element type, for example
C01-B1-L1-ARC-CS-SH-05for the glass wall.
learn with this build
Your project on this campus type
L7 Super expert. Plan the three build phases of a flagship campus, write one local annex for a country of your choice, and specify the digital twin: ten data points, each linked to an element code and a decision. Open L7 Super expert
practice files
Download and open the model
A practice model of this campus type in an open format (IFC), at LOD 200. It holds 194 module shells on 2 floors. Each shell carries its element code, its level of development and the space it belongs to. Doors, walls and furniture are left for you to add.
- Practice model, Flagship campus (IFC file)
- Element list, Flagship campus (CSV file, opens in any spreadsheet)
- Open the model in any free viewer that reads open IFC files. Click one module and read its properties: you will see the code CS-SH-01 and LOD 200.
For learning only. Not a drawing for building.