campus build · S1 · satellite tier
Mobile unit
One module that can be placed in a day. It is a help desk and a small project room, used to open a new town before a larger campus arrives.
at a glance
Size and capacity
- Tier: Satellite
- Modules: 1
- Floors: 1
- Floor area: about 14 m2
- Learners at one time: 4
- Rooms: 1
Used for. Enrolment days, mentor meetings, a first presence at a partner site.
space schedule
Spaces, modules and seats
| Space | Group | Count | Modules | Seats |
|---|---|---|---|---|
| Welcome desk and project table | Welcome | 1 | 1 | 4 |
| Total | 1 | 4 |
- Washrooms are those of the host site. Check the walking route to them is step-free.
- Power comes from one outdoor socket of the host site, or from the solar roof and a battery.
- The unit keeps its own fire extinguisher, first-aid kit and exit sign.
element list
Coded elements and quantities
Every line uses a code from the element library. No maker is named. Quantities are worked out from the space schedule by the rules of the standard.
| Code | Element | Quantity | Unit |
|---|---|---|---|
| CS-SH-01 | Module shell, 2.4 x 5.8 x 2.9 m | 1 | each |
| CS-SH-08 | Access ramp, step-free entrance | 1 | each |
| CS-IN-05 | Floor finish, dry areas | 14 | m2 |
| CS-FU-06 | Learner seat | 4 | each |
| CS-SV-01 | Sub-board, per floor | 1 | each |
| CS-SV-02 | Cooling unit, per room | 1 | each |
| CS-SV-03 | Smoke detector and sounder group | 2 | each |
| CS-SV-04 | Comms cabinet | 1 | each |
| CS-SV-05 | Solar array, roof | 1 | kW |
| CS-SV-06 | Emergency light and exit sign group | 3 | each |
Reference design v0.1. Planning values for teaching and early design. A licensed local engineer and the local authority confirm every real project.
build order
How it is put together
- Level the base and check water runs away from it.
- Lift the module into place and anchor it.
- Fit the ramp, connect power and test the lights.
- Place furniture, signs and the first-aid kit.
- Walk the exit route and record the hand-over.
model files
File names for this build
C01-B1-L1-ARC: architecture model, floor 1C01-B1-L1-STR: structure model, floor 1C01-B1-L1-MEP: services model, floor 1- Replace C01 with the number of the real campus. The element code follows when a file holds one element type, for example
C01-B1-L1-ARC-CS-SH-05for the glass wall.
learn with this build
Your project on this campus type
L1 Basic. Label the parts of the mobile unit on a printed picture and say what each part does. Open L1 Basic
practice files
Download and open the model
A practice model of this campus type in an open format (IFC), at LOD 200. It holds 1 module shells on 1 floor. Each shell carries its element code, its level of development and the space it belongs to. Doors, walls and furniture are left for you to add.
- Practice model, Mobile unit (IFC file)
- Element list, Mobile unit (CSV file, opens in any spreadsheet)
- Open the model in any free viewer that reads open IFC files. Click one module and read its properties: you will see the code CS-SH-01 and LOD 200.
For learning only. Not a drawing for building.