Author it, Train it, Learn it, Earn it
Back

campus build · S2 · satellite tier

Satellite pair

Two modules joined side by side to make one small learning studio for 14 learners.

at a glance

Size and capacity

  • Tier: Satellite
  • Modules: 2
  • Floors: 1
  • Floor area: about 28 m2
  • Learners at one time: 14
  • Rooms: 1

Used for. A first classroom in a village, a housing community or a workplace yard.

space schedule

Spaces, modules and seats

Space schedule, Satellite pair
SpaceGroupCountModulesSeats
Small learning studioLearn1214
Total214
  • The wall between the two modules is left open, so the room is about 4.8 m wide and 5.8 m long.
  • Seats follow the same ratio as the full studio: about 1.9 m2 for each learner.
  • Washrooms are those of the host site, or a service module is added (see the six-module satellite).

element list

Coded elements and quantities

Every line uses a code from the element library. No maker is named. Quantities are worked out from the space schedule by the rules of the standard.

Element list, Satellite pair
CodeElementQuantityUnit
CS-SH-01Module shell, 2.4 x 5.8 x 2.9 m2each
CS-SH-05Glass curtain wall panel5.5m2
CS-SH-06Sliding glass door1each
CS-SH-08Access ramp, step-free entrance1each
CS-IN-05Floor finish, dry areas28m2
CS-FU-06Learner seat14each
CS-SV-01Sub-board, per floor1each
CS-SV-02Cooling unit, per room1each
CS-SV-03Smoke detector and sounder group2each
CS-SV-04Comms cabinet1each
CS-SV-05Solar array, roof2kW
CS-SV-06Emergency light and exit sign group3each

Reference design v0.1. Planning values for teaching and early design. A licensed local engineer and the local authority confirm every real project.

build order

How it is put together

  1. Level the base for two modules.
  2. Place and bolt the two modules, then seal the joint in the roof.
  3. Fit the sliding glass door, the ramp and the board wall.
  4. Connect power, cooling and data, then test each.
  5. Place 14 seats, check the aisle and record the hand-over.

model files

File names for this build

  • C01-B1-L1-ARC: architecture model, floor 1
  • C01-B1-L1-STR: structure model, floor 1
  • C01-B1-L1-MEP: services model, floor 1
  • Replace C01 with the number of the real campus. The element code follows when a file holds one element type, for example C01-B1-L1-ARC-CS-SH-05 for the glass wall.

learn with this build

Your project on this campus type

L2 Awareness. Open the satellite pair in a viewer. Find five elements and write their codes, sizes and levels of development. Open L2 Awareness

practice files

Download and open the model

A practice model of this campus type in an open format (IFC), at LOD 200. It holds 2 module shells on 1 floor. Each shell carries its element code, its level of development and the space it belongs to. Doors, walls and furniture are left for you to add.

For learning only. Not a drawing for building.