Author it, Train it, Learn it, Earn it
Back

campus build · S4 · satellite tier

Studio satellite

Four modules joined to make one full learning studio for 30 learners, with a movable wall.

at a glance

Size and capacity

  • Tier: Satellite
  • Modules: 4
  • Floors: 1
  • Floor area: about 56 m2
  • Learners at one time: 30
  • Rooms: 1

Used for. A full class in one room: the smallest campus that meets the 30-seat studio rule.

space schedule

Spaces, modules and seats

Space schedule, Studio satellite
SpaceGroupCountModulesSeats
Open learning studioLearn1430
Total430
  • Four modules side by side give about 56 m2. That holds the 48 m2 clear area the studio rule asks for, plus a store wall.
  • The movable wall lets the room work as two groups of 15.
  • A room for 30 people needs two ways out. The second door is on the opposite side from the first.

element list

Coded elements and quantities

Every line uses a code from the element library. No maker is named. Quantities are worked out from the space schedule by the rules of the standard.

Element list, Studio satellite
CodeElementQuantityUnit
CS-SH-01Module shell, 2.4 x 5.8 x 2.9 m4each
CS-SH-05Glass curtain wall panel5.5m2
CS-SH-06Sliding glass door1each
CS-SH-08Access ramp, step-free entrance1each
CS-IN-03Folding partition15m2
CS-IN-05Floor finish, dry areas56m2
CS-IN-07Fire-exit door with push bar1each
CS-FU-06Learner seat30each
CS-SV-01Sub-board, per floor1each
CS-SV-02Cooling unit, per room1each
CS-SV-03Smoke detector and sounder group2each
CS-SV-04Comms cabinet1each
CS-SV-05Solar array, roof5kW
CS-SV-06Emergency light and exit sign group3each

Reference design v0.1. Planning values for teaching and early design. A licensed local engineer and the local authority confirm every real project.

build order

How it is put together

  1. Level the base for four modules.
  2. Place and bolt the modules one by one, then seal the roof joints.
  3. Fit the glass wall, both doors, the ramp and the movable wall.
  4. Connect and test power, cooling, data, smoke detectors and emergency lights.
  5. Place 30 seats, walk both exit routes and record the hand-over.

model files

File names for this build

  • C01-B1-L1-ARC: architecture model, floor 1
  • C01-B1-L1-STR: structure model, floor 1
  • C01-B1-L1-MEP: services model, floor 1
  • Replace C01 with the number of the real campus. The element code follows when a file holds one element type, for example C01-B1-L1-ARC-CS-SH-05 for the glass wall.

learn with this build

Your project on this campus type

L3 Foundation. Build the studio satellite from library elements: four modules, glass wall, two doors, ramp, movable wall and 30 seats. Open L3 Foundation

practice files

Download and open the model

A practice model of this campus type in an open format (IFC), at LOD 200. It holds 4 module shells on 1 floor. Each shell carries its element code, its level of development and the space it belongs to. Doors, walls and furniture are left for you to add.

For learning only. Not a drawing for building.