campus build · S6 · satellite tier
Full satellite
Six modules on one floor: a learning studio, a welcome module and a service module. It is the complete satellite campus of the standard.
at a glance
Size and capacity
- Tier: Satellite
- Modules: 6
- Floors: 1
- Floor area: about 84 m2
- Learners at one time: 30
- Rooms: 4
Used for. A small town campus that stands on its own, with its own washrooms and pantry.
space schedule
Spaces, modules and seats
| Space | Group | Count | Modules | Seats |
|---|---|---|---|---|
| Open learning studio | Learn | 1 | 4 | 30 |
| Welcome module: desk, project table for 6 and two phone booths | Welcome | 1 | 1 | 6 |
| Service module: washrooms with one accessible cubicle, and a pantry | Support | 1 | 1 | - |
| Total | 6 | 36 |
- Everything is on one floor, so the whole campus is step-free.
- The service module sits at the end, so its water and drain run in one short line.
- The welcome module faces the entrance, so a visitor is seen at once.
element list
Coded elements and quantities
Every line uses a code from the element library. No maker is named. Quantities are worked out from the space schedule by the rules of the standard.
| Code | Element | Quantity | Unit |
|---|---|---|---|
| CS-SH-01 | Module shell, 2.4 x 5.8 x 2.9 m | 6 | each |
| CS-SH-05 | Glass curtain wall panel | 5.5 | m2 |
| CS-SH-06 | Sliding glass door | 1 | each |
| CS-SH-08 | Access ramp, step-free entrance | 1 | each |
| CS-IN-03 | Folding partition | 15 | m2 |
| CS-IN-05 | Floor finish, dry areas | 70 | m2 |
| CS-IN-06 | Floor and wall finish, wet areas | 14 | m2 |
| CS-IN-07 | Fire-exit door with push bar | 1 | each |
| CS-FU-03 | Phone booth | 2 | each |
| CS-FU-06 | Learner seat | 30 | each |
| CS-SV-01 | Sub-board, per floor | 1 | each |
| CS-SV-02 | Cooling unit, per room | 4 | each |
| CS-SV-03 | Smoke detector and sounder group | 5 | each |
| CS-SV-04 | Comms cabinet | 1 | each |
| CS-SV-05 | Solar array, roof | 7 | kW |
| CS-SV-06 | Emergency light and exit sign group | 6 | each |
Reference design v0.1. Planning values for teaching and early design. A licensed local engineer and the local authority confirm every real project.
build order
How it is put together
- Level the base and lay the water and drain line to the service end.
- Place the four studio modules, then the welcome and service modules.
- Fit the glass wall, doors, ramp and movable wall. Waterproof the wet rooms up to 1.5 m.
- Connect and test power, cooling, water, drainage, data and the fire system.
- Place furniture and phone booths, walk both exit routes and record the hand-over.
model files
File names for this build
C01-B1-L1-ARC: architecture model, floor 1C01-B1-L1-STR: structure model, floor 1C01-B1-L1-MEP: services model, floor 1- Replace C01 with the number of the real campus. The element code follows when a file holds one element type, for example
C01-B1-L1-ARC-CS-SH-05for the glass wall.
learn with this build
Your project on this campus type
L4 Practitioner. Link the architecture, structure and services models of the full satellite. Close every hard clash and take off the element list. Open L4 Practitioner
practice files
Download and open the model
A practice model of this campus type in an open format (IFC), at LOD 200. It holds 6 module shells on 1 floor. Each shell carries its element code, its level of development and the space it belongs to. Doors, walls and furniture are left for you to add.
- Practice model, Full satellite (IFC file)
- Element list, Full satellite (CSV file, opens in any spreadsheet)
- Open the model in any free viewer that reads open IFC files. Click one module and read its properties: you will see the code CS-SH-01 and LOD 200.
For learning only. Not a drawing for building.